Kernel Density Estimation of Electromyographic Signals and Ensemble Learning for Highly Accurate Classification of a Large Set of Hand/Wrist Motions.


Por: Ghaderi P, Nosouhi M, Jordanic M, Marateb HR, Mañanas MA and Farina D

Publicada: 9 mar 2022 Ahead of Print: 9 mar 2022
Categoría: Neuroscience (miscellaneous)

Resumen:
The performance of myoelectric control highly depends on the features extracted from surface electromyographic (sEMG) signals. We propose three new sEMG features based on the kernel density estimation. The trimmed mean of density (TMD), the entropy of density, and the trimmed mean absolute value of derivative density were computed for each sEMG channel. These features were tested for the classification of single tasks as well as of two tasks concurrently performed. For single tasks, correlation-based feature selection was used, and the features were then classified using linear discriminant analysis (LDA), non-linear support vector machines, and multi-layer perceptron. The eXtreme gradient boosting (XGBoost) classifier was used for the classification of two movements simultaneously performed. The second and third versions of the Ninapro dataset (conventional control) and Ameri's movement dataset (simultaneous control) were used to test the proposed features. For the Ninapro dataset, the overall accuracy of LDA using the TMD feature was 98.99 ± 1.36% and 92.25 ± 9.48% for able-bodied and amputee subjects, respectively. Using ensemble learning of the three classifiers, the average macro and micro-F-score, macro recall, and precision on the validation sets were 98.23 ± 2.02, 98.32 ± 1.93, 98.32 ± 1.93, and 98.88 ± 1.31%, respectively, for the intact subjects. The movement misclassification percentage was 1.75 ± 1.73 and 3.44 ± 2.23 for the intact subjects and amputees. The proposed features were significantly correlated with the movement classes [Generalized Linear Model (GLM); P-value < 0.05]. An accurate online implementation of the proposed algorithm was also presented. For the simultaneous control, the overall accuracy was 99.71 ± 0.08 and 97.85 ± 0.10 for the XGBoost and LDA classifiers, respectively. The proposed features are thus promising for conventional and simultaneous myoelectric control.

Filiaciones:
Ghaderi P:
 The Biomedical Engineering Department, Engineering Faculty, University of Isfahan, Isfahan, Iran

 Laboratory of Sensory Processing, Brain Mind Institute, Faculty of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland

Nosouhi M:
 The Biomedical Engineering Department, Engineering Faculty, University of Isfahan, Isfahan, Iran

Jordanic M:
 Biomedical Engineering Research Centre (CREB), Automatic Control Department (ESAII), Universitat Politècnica de Catalunya-Barcelona Tech (UPC), Barcelona, Spain

Marateb HR:
 The Biomedical Engineering Department, Engineering Faculty, University of Isfahan, Isfahan, Iran

 Biomedical Engineering Research Centre (CREB), Automatic Control Department (ESAII), Universitat Politècnica de Catalunya-Barcelona Tech (UPC), Barcelona, Spain

Mañanas MA:
 Biomedical Engineering Research Centre (CREB), Automatic Control Department (ESAII), Universitat Politècnica de Catalunya-Barcelona Tech (UPC), Barcelona, Spain

 CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain

Farina D:
 Department of Bioengineering, Imperial College London, London, United Kingdom
ISSN: 16624548





Frontiers in Neuroscience
Editorial
FRONTIERS MEDIA SA, AVENUE DU TRIBUNAL FEDERAL 34, LAUSANNE CH-1015, SWITZERLAND, Suiza
Tipo de documento: Article
Volumen: 16 Número:
Páginas: 796711-796711
WOS Id: 000783640800001
ID de PubMed: 35356057
imagen Open Access

MÉTRICAS